Calibrate Capacitance
It is used to check the corresponding relationship of capacitance and position between the cutting head and the workpiece, so as to move Z-axis up and down in real time and ensure the relative distance between the cutting head and the workpiece is unchanged.
To calibrate capacitance, do the following:
To open Follow-up Control dialog box, do one of the following:
In the common tool bar, click .
In the menu bar, click System → Follow Control.
Select one of the following to move the cutting head to the position about 5mm far from the workpiece surface, and keep the workpiece still all the time:
If you have never calibrated capacitance, click the axis direction button.
If you have calibrated capacitance before, click .
To eliminate zero drift caused by velocity loop controlling, click . The cutting head slightly moves back and forth to compensate the error caused by zero drift.
Click .
The system starts to calibrate capacitance for 20s.