维宏LOGO
Search Results for

    Show / Hide Table of Contents

    Wiring and IO configuration

    NcStudio V10 CCD System uses Lambda 3S controller.

    See figure below for wiring and IO ports of Lambda 3S.

    Table below describes details of 7 input and 5 output ports.

    • X__ represents input ports
    • Y__ represents output ports
    PIN Address Description
    X00 00100 Negative limit in X-axis, also used as origin switch
    X01 00101 Negative limit in Y-axis, also used as origin switch
    X02 00102 Positive limit in Z-axis, also used as origin switch
    X03 00103 Emergency stop
    X04 00104 Tool sensor signal
    X05 00105 Vacuum pressure alarm signal
    X06 00106 Spindle alarm
    Y00 10016 Spindle ON
    Y01 10017 Vacuum pump
    Y02 10018 Lube
    Y03 10019 Light source
    Y04 10020 Reserved for customization
    In This Article